Fixed Flow Meter Specialists - Micronics Ltd

  Learn More About The World's Easy To Use Flow Meter  


Download the Micronics Flow:watch 2010

Fixed Flow Meter Specialists - Micronics Ltd
The World's Easy To Use Fixed Flow Meter - Languages

Fixed Products


U3000
Fixed Flow Meters - Click here to see the U3000
• For “clean” liquid monitoring
• To suit pipes 13mm-5000mm
• Non invasive sensing
• Easy to use

PSL
Fixed Flow Meters - Click here to see the PSL
• Monitors and controls multiple
pumps
• Combined with software for ease of use

 
AVFM-II
Fixed Flow Meters - Click here to see the AVFM-II
• For “clean” liquid monitoring
• To suit pipes 50-400mm
• Non invasive sensing
• Portable and Easy to use

 
Ultraflo D5000
Fixed Flow Meters - Click here to see the DFM-4.0
• For “dirty” liquid monitoring
• To suit pipes 13mm-4500mm
• Non invasive sensing
• Easy to use

DFS-II
Fixed Flow Meters - Click here to see the DFS-II
• For “dirty” liquids
• Adjustable relay/setpoint outputs
• Non invasive sensing
• Easy to use

 
OCF4.0
Fixed Flow Meters - Click here to see the OCF-IV
• For “clean” liquid monitoring
• To suit pipes 50-400mm
• Non invasive sensing
• Portable and Easy to use

 
LIT-25
Fixed Flow Meters - Click here to see the LIT-25
• For level monitoring
• Versatile choice of sensor types
• Easy to use



SLT-32
Fixed Flow Meters - Click here to see the SLT-32
• For open channel and level
monitoring
• 50000 point logger option and
software
• Versatile choice of channel types
• Easy to use
 
TFT-32
Fixed Flow Meters - Click here to see the TFT-32
• For indicating the presence of
flow in closed pipes
• Combine up to 32 units for site
wide monitoring
• Easy to use
       
       

 

Ultraflo 3000 Click here to top

Fixed Flow Meters - Click here to see the Ultraflo 3000

Brochure

Click Here too Download the manualManual

Enclosure:- The U3000/U4000 enclosure is IP65 rated.
‘A’ Transducers:- 13mm OD to 115mm OD pipes.
‘B’ Transducers:- 50mm OD to 2000mm OD pipes.
Optional Transducers:- For pipes 1500mm up to 5000mm contact Micronics.
Transducer Operating Temp:- ‘A’&‘B’ -20°C to +135°C.
Outputs:– Opto Isolated 0/4 –20mA; RS 232/USB (U4000 ONLY); Pulse Output – Programmable Pulse Width from 2ms - 500ms; Two programmable Alarms-High/Low flow, Volume or error.
Data Logger (U4000 ONLY):– Built in data logger with 198,000 data points which can be configured to log flow rate and/or total flow. Real time or stored data can be displayed locally in text or graph format, and downloaded via RS232 or USB port to Windows based PC.

 

 

AVFM-II Area- Velocity Flow Meter

Fixed Flow Meters - Click here to see the AVFM-II
Monitor flows through partially full pipes or open channels.
Eliminates the need for flumes or weirs.
Automatic temperature compensation.
Barriers for I S operation.
50,000 point data logger.
Logger software included. Runs on Windows 95, 98, 2000, XP or NT.

Enclosure:- Watertight and dustproof (IP66).
Power Input:- 100-130VAC and 200-250VAC, 50/60HZ., 7.5 watts 12VDC or 24VDC.
Outputs:- 2x Isolated 4-20mA into 1000 ohm load. Programmable for Flow, Head or Velocity. RS 232 Option Serial and Windows Software.
Relays:- 3 x form ‘C’ dry contacts rated 5 amp SBDT Programmable for Flow Proportional pulse (sampler/totalizer) flow and/or level alarm.
Velocity Range:- 0.03 to 6.2m/sec.
Level Range:- Minimum Head 25mmto maximum head 4.5m. Accuracy:-
Level:- 0.25% of Range,
Velocity:- +/-2% of Reading,
Linearity and Repeatability:- +/- 0.1%.

Click here to top

Brochure

Click Here too Download the manualClick Here too Download the manual Manual

 

Ultraflow D5000 Click here to top

Fixed Flow Meters - Click here to see the DFM-4.0
Watertight enclosure.
RFI rejection Filters.
Signal strength Indicator.
Backflow protection.

Pipe Range:- >13mm up to 4.5m.
Power Input:- 100–240VAC, 50/60Hz, 3watts max.
Flow Rate Range:- -12.2m/s to 12m/s in most applications.
Accuracy:- +/-2% of full scale. Requires solids
or bubbles of minimum size 100 microns,
minimum concentration 75ppm.
Repeatability:- +/- 0.1%.
Linearity:- +/-0.5% of full scale.
Display:- White, backlit matrix - displays flow rate, totalizer, relay states, operating mode and calibration menu.
Output:- Isolated/4–20mA(1000ohm load max.) 5amp rated SPDT relays, programmable flow alarms and/or proportional pulse. Adjustable sensitivity and damping.
Electronics Operating Temp:- -23°C to +60°C.
Sensor Operating Temp:- -40°C to +120°C.
Options:- 9-32VDC. Intrinsic Safety Barriers, for sensor mounting in hazardous locations, SE3H High Temperature model rated to 150°C, ISE Insertion type for special applications. Enclosure Heater for outdoor installation, 16watt thermostatically control to -40°C. Data Logger Built-in 2 million point logger with USB output and Windows software.

Click here to top

Brochure

Click Here too Download the manual Manual

 

DFS-II Doppler Flow Switch Click here to top

Fixed Flow Meters - Click here to see the DFS-II
Suitable for liquids or solids.
Easy to install.
Watertight, dustproof (IP67).
Low cost.

Electronics:- Wall mounting 175x125x75mm.
Power Input:- 100 – 130VAC, 50/60Hz, 4.2watts.
200 – 260VAC, 50/60Hz, 4.8watts. Optional
24VDC, 3.6watts. Surge protection on power Input.
Output:- 5amp relay, DPDT.
Set Point:- On/Off adjustment – 0.1 to 3m
per sec.
Time Delay:- Switch selectable.
Failsafe Mode:- Switch selectable.
Indication:- Relay status and signal strength LED’s.
Pipe Range:- 12.5mm ID to 4.5m ID.
Sensor cable:- Surge protected, 5m-Shielded Coax
Optional:- 15m.
Hazardous Locations:- Intrinsic safety
Barriers option.

Click here to top

Brochure

Click Here too Download the manual Manual

 

OCF4.0

Fixed Flow Meters - Click here to see the OCF-IV
Simple 3-Key calibration.
Password protected.
RS232 Serial output.
50000 point logger.
Windows software.

Enclosure:- Polycarbonate (IP66). Shatterproof clear Front Panel.
Power:- 100-130VAC/200-250VAC, 50/60HZ & 6.2watts max.
Option:- 9-36VDC.
Outputs:- Isolated 4-20mA 1000 ohm load maximum. Can be user-configured to 0-5V output. USB and isolated RS232 for data log transfer by cable connection to a PC, or dial-up connection through modems. Programmable baud rates of 9600 or 19,200. 3 Relays, for "C" dry contacts rated 5 amp SPDT, programmable level alarm, flow proportional pulse (sampler/totalizer) echo loss and air temperature alarm.
Sensor Specification:- Maximum range: 4.57m.
Dead Band:- Programmable. Minimum 200mm.
Beam Angle:- 8°.

Click here to top

Brochure

Click Here too Download the manualClick Here too Download the manualManual

 

 