Enclosure:- The U3000/U4000 enclosure is IP65 rated. ‘A’ Transducers:- 13mm OD to 115mm OD pipes. ‘B’ Transducers:- 50mm OD to 2000mm OD pipes. Optional Transducers:- For pipes 1500mm up to 5000mm contact Micronics. Transducer Operating Temp:- ‘A’&‘B’ -20°C to +135°C. Outputs:– Opto Isolated 0/4 –20mA; RS 232/USB (U4000 ONLY); Pulse Output – Programmable Pulse Width from 2ms - 500ms; Two programmable Alarms-High/Low flow, Volume or error. Data Logger (U4000 ONLY):– Built in data logger with 198,000 data points which can be configured to log flow rate and/or total flow. Real time or stored data can be displayed locally in text or graph format, and downloaded via RS232 or USB port to Windows based PC.
AVFM-II Area- Velocity Flow Meter
Monitor flows through partially full pipes or open channels. Eliminates the need for flumes or weirs. Automatic temperature compensation. Barriers for I S operation. 50,000 point data logger. Logger software included. Runs on Windows 95, 98, 2000, XP or NT.
Enclosure:- Watertight and dustproof (IP66). Power Input:- 100-130VAC and 200-250VAC, 50/60HZ., 7.5 watts 12VDC or 24VDC. Outputs:- 2x Isolated 4-20mA into 1000 ohm load. Programmable for Flow, Head or Velocity. RS 232 Option Serial and Windows Software. Relays:- 3 x form ‘C’ dry contacts rated 5 amp SBDT Programmable for Flow Proportional pulse (sampler/totalizer) flow and/or level alarm. Velocity Range:- 0.03 to 6.2m/sec. Level Range:- Minimum Head 25mmto maximum head 4.5m.
Accuracy:- Level:- 0.25% of Range, Velocity:- +/-2% of Reading, Linearity and Repeatability:- +/- 0.1%.
Watertight enclosure. RFI rejection Filters. Signal strength Indicator. Backflow protection.
Pipe Range:- >13mm up to 4.5m. Power Input:- 100–240VAC, 50/60Hz, 3watts max. Flow Rate Range:- -12.2m/s to 12m/s in most applications. Accuracy:- +/-2% of full scale. Requires solids
or bubbles of minimum size 100 microns,
minimum concentration 75ppm. Repeatability:- +/- 0.1%. Linearity:- +/-0.5% of full scale. Display:- White, backlit matrix - displays flow rate, totalizer, relay states, operating mode and calibration menu. Output:- Isolated/4–20mA(1000ohm load max.) 5amp rated SPDT relays, programmable flow alarms and/or proportional pulse. Adjustable sensitivity and damping. Electronics Operating Temp:- -23°C to +60°C. Sensor Operating Temp:- -40°C to +120°C. Options:- 9-32VDC. Intrinsic Safety Barriers, for sensor mounting in hazardous locations, SE3H High Temperature model rated to 150°C, ISE Insertion type for special applications. Enclosure Heater for outdoor installation, 16watt thermostatically control to -40°C. Data Logger Built-in 2 million point logger with USB output and Windows software.
Simple 3-Key calibration. Password protected. RS232 Serial output. 50000 point logger. Windows software.
Enclosure:- Polycarbonate (IP66). Shatterproof clear Front Panel. Power:- 100-130VAC/200-250VAC, 50/60HZ & 6.2watts max. Option:- 9-36VDC. Outputs:- Isolated 4-20mA 1000 ohm load maximum. Can be user-configured to 0-5V output. USB and isolated RS232 for data log transfer by cable connection to a PC, or dial-up connection through modems. Programmable baud rates of 9600 or 19,200. 3 Relays, for "C" dry contacts rated 5 amp SPDT, programmable level alarm, flow proportional pulse (sampler/totalizer) echo loss and air temperature alarm. Sensor Specification:- Maximum range: 4.57m. Dead Band:- Programmable. Minimum 200mm. Beam Angle:- 8°.