UF DS200 Flow Switch

Non contact Doppler flow switch.

Description

  • For “dirty” liquids
  • Adjustable relay/setpoint outputs
  • Non-invasive sensing
  • Easy to use

Mount the ultrasonic sensor on the outside of metal or plastic pipes. The sensor continuously injects high frequency sound through the pipe wall and into the moving fluid where acoustic pulses are reflected back to the sensor from particles or bubbles in the fluid.

Flow rates of most liquids can be accurately controlled including acids, caustics, lubrication fluids, chemicals, abrasives, waste water and sludge. There are no moving parts and no sensor maintenance is required.

The compact, water tight electronics enclosure includes adjustable controls with separate ON and OFF relay set-points and time delay. A LED bargraph for flow rate and set points plus relay status are included.

Installation can be made while the flow system is in full operation. No contact is made with the moving fluid and no holes are drilled in the pipe. There is no fouling or scale build-up on the sensor.

Description

  • For “dirty” liquids
  • Adjustable relay/setpoint outputs
  • Non-invasive sensing
  • Easy to use

Mount the ultrasonic sensor on the outside of metal or plastic pipes. The sensor continuously injects high frequency sound through the pipe wall and into the moving fluid where acoustic pulses are reflected back to the sensor from particles or bubbles in the fluid.

Flow rates of most liquids can be accurately controlled including acids, caustics, lubrication fluids, chemicals, abrasives, waste water and sludge. There are no moving parts and no sensor maintenance is required.

The compact, water tight electronics enclosure includes adjustable controls with separate ON and OFF relay set-points and time delay. A LED bargraph for flow rate and set points plus relay status are included.

Installation can be made while the flow system is in full operation. No contact is made with the moving fluid and no holes are drilled in the pipe. There is no fouling or scale build-up on the sensor.

Request a Quote

Brochures

  • UF DS200 Brochure

User Manuals

  • UF DS200 Manual

Videos

There are no case studies available for this product

Technical Information

Electronics:- Wall mounting 107x57x61.5mm
Power Input:– 100 – 240VAC, Optional 12 – 24VDC, (3 watts)
Output:– 5amp relay, DPDT
Set Point:– Field-adjustable with separate on/off set-points or select Hi flow alarm or Lo flow alarm mode
Time Delay:- Adjustable 0-80 seconds
Failsafe Mode:– Switch selectable
Indication:– Flow rate LED bargraph, relay status LED
Pipe Range:– 12.5mm ID to 4.5m ID
Sensor cable:– 6m-Shielded Coax
Optional:– 150m

Ultrasonic Flow Switch