New: UF D5500 Fixed Clamp-on Flow Meter

Best value fixed non-invasive, clamp-on, measurement solution for dirty water applications

Description

  • Best value solution for “dirty” liquid monitoring including: Raw Sewage, Viscous Liquids, Sludge & Slurries, Solvents, Pulp Stock, Food Products, Lubricating Oils & Crude Oil.
  • To suit pipes 12.7mm-4500mm
  • No Pipe cutting, No contact, Non-invasive sensing
  • Easy to use
  • Watertight enclosure
  • New 26 million point data logger now as standard
  • Improved signal stability
  • Enhanced diagnostics
  • New Modbus and HART serial communications now optional feature

Description

  • Best value solution for “dirty” liquid monitoring including: Raw Sewage, Viscous Liquids, Sludge & Slurries, Solvents, Pulp Stock, Food Products, Lubricating Oils & Crude Oil.
  • To suit pipes 12.7mm-4500mm
  • No Pipe cutting, No contact, Non-invasive sensing
  • Easy to use
  • Watertight enclosure
  • New 26 million point data logger now as standard
  • Improved signal stability
  • Enhanced diagnostics
  • New Modbus and HART serial communications now optional feature
Request a Quote

Brochures

  • UFD5500 Brochure

User Manuals

  • UFD5500 Manual

Technical Information

Pipe Range:– >12.7mm up to 4.5m
Power Input:– 100–240VAC, 50/60Hz, 10VA max
Flow Rate Range:0.03m/s to 12.2m/s in most applications
Accuracy:– +/-2% of reading or 0.03m/s whichever is greater. Requires solids or bubbles of minimum size 100 microns, minimum concentration 75ppm
Repeatability:– +/- 0.1%
Linearity:– +/-0.5% of full scale
Display:– White, backlit matrix – displays flow rate, relay states, 16-digit Totaliser, operating mode and calibration menu
Output:– Isolated 4–20mA (1000 ohm load max.) or 0-5VDC (Field Selectable)
Control Relays:– Qty 2, rated 5 amp SPDT, programmable flow alarm and/or proportional pulse
Data LoggerNew Standard built-in 26 million point logger with USB output and Windows software
Enclosure Watertight, dust tight; NEMA4X (IP 66} polyester with a clear polycarbonate face
Electronics Operating Temp:– -23°C to +60°C
Sensor Operating Temp:– -40° to +150°C (-40° to 300°F)
Options:

  • New Industrial Automation Protocols: Modbus RTU via RS485 or HART (field selectable)
  • New Sensors: Intrinsic Safety Barriers for mounting in hazardous locations contact Micronics
  • Enclosure Heater: 9-32VDC. Enclosure Heater and Thermostat for outdoor installation.

Request A Quote